New Polymer Compounds to Limit Hydrolytic Degradation: Clariant at MD&M West

Published on 2019-02-06. Edited By : SpecialChem

TAGS:  Medical    

New MEVOPUR materialsClariant, a world leader in specialty chemicals, is introducing new polymer compounds specially formulated to limit or even eliminate hydrolytic degradation, which is known to affect certain materials commonly used in catheters. Offered under the MEVOPUR brand name, the new resins are being presented for the first time at the MD&M West tradeshow taking place February 5-7, 2019, in Anaheim, CA. Clariant is exhibiting in Booth 2049.

PEBA & TPU Compounds


In polyether block amides (PEBA) and certain thermoplastic polyurethanes (TPU), adsorbed moisture can cause a breakdown of the polymer chains and reduce the mechanical properties, rendering these ductile and tough materials brittles. This effect may be especially pronounced in resins with radiopaque fillers that make them visible to physicians and surgeons when exposed to X rays. Even with careful pre-drying of the ingredients prior to compounding and tube extrusion, hydrolysis remains a risk. Moisture also can condense from the atmosphere, even inside foil-lined packaging, due to changes in temperature during transportation or storage.

“This hydrolysis effect is variable and difficult to predict,” explains Eric Rohr, Medical & Pharmaceutical Segment Manager, North America. “Uncontrolled it creates quality and reliability risks, increasing the need for vigilance in QA procedures. In addition, the shelf-life of the polymer compounds is less predictable and may be shortened to only a few months. After several years of research and testing, we are pleased to be able to limit the risk of hydrolysis and breakage in these materials, thereby helping device manufacturers improve the reliability of catheters.”

One of the first indications of chain scission is an increased melt-flow index (MFI). So, Clariant researchers compared the MFI of a standard, unmodified tungsten-filled PEBA 35 Shore A compound against a sample of the new MEVOPUR.

TEST RESULTS


After 10 weeks storage under humid conditions, the unmodified compound showed more than double the original MFI values, and a wider spread, indicating chain scission and reduction in molecular weight. In comparison, the MEVOPUR compound maintained its MFI values in the same range as before the test began. These results indicate that the polymer chains had not been broken to same extent.

Similar results were noted in testing of tungsten-filled aliphatic thermoplastic polyurethane (TPU) Shore 90A compound. Again, the MFI of the MEVOPUR compound was hardly affected by the humid conditions.